Message Overview:
Message Name:
APU BATT VOLTAGE - AMP - TEMP INDICATION ERRONEOUS
| Message Code: | 243OBS001 |
| Effectivity: | All |
| System: | Battery System |
| System Description: | 24-32-00 |
| Schematic Diagram: | 24-32-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-32-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The Auxiliary Power Unit (APU) Battery voltage, amperage and/or temperature indication on the DC synoptic page are erroneous.
Possible Causes:
- Auxiliary Power Unit Battery (A89)
- Auxiliary Power Unit Battery Charger (A90)
- AC Power Center (ACPC) (A54)
- AC Power Center (ACPC) External AC/DC Converter Card
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Disconnect the APU Battery | AMM 24-32-00-040-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Connect the APU Battery | AMM 24-32-00-440-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Battery Chargers | AMM 24-32-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Battery Chargers | AMM 24-32-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the APU Battery | AMM 24-32-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Battery | AMM 24-32-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) | AMM 24-51-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) | AMM 24-51-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the AC Power Center (ACPC) External AC-to-DC Converter | AMM 24-51-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the AC Power Center (ACPC) External AC-to-DC Converter | AMM 24-51-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Use the PMAT to access CAIMS active or stored faults.
- If there are ATA 24 related faults present, troubleshoot these faults first and continue with next step.
- If no related ATA 24 faults are present, continue with next step.
- Swap the APU BATT charger with the Avionic BATT charger.
- If the system checks are good, replace APU BATT charger and do close out.
- If fault remains, continue with next step.
- Perform a continuity check between the APU BATT and the APU BATT charger as follows:
From To Result A89P1-Y A90P1-Y A89P1-K A90P1-K A89P1-J A90P1-J A89P1-H A90P1-H A89P1-X A90P1-X NOTE: Make sure there is no continuity to ground on the listed wires as well.
- If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Access the ACPC logic assembly and replace the ACPC External AC/DC Converter Card.
- If the system checks are good, do close out.
- If fault remains, continue with next step.
- Perform the ACPC logic card isolation procedure.
- If faulty ACPC card is found, replace card as required and do close out.
- If no cards are found faulty, continue with next step.
- Replace the APU battery.
- If the system checks are good, do close out.
- If fault remains, continue with next step.
- Replace ACPC.
- Do close out.