06/29/21
Message Overview:
Message Name:
HYDRAULIC PRESSURE SWITCH INDICATION FAILURE
| Message Code: | 293OBS011 |
| Effectivity: | All |
| System: | Engine Indicating |
| System Description: | 29-30-00 |
| Schematic Diagram: | 29-12-00 [ Global Express ] [ G5000 ] [ GlobalXRS ] 29-13-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 29-00-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
A failure of the Hydraulic System 1, Hydraulic System 2, Hydraulic System 3 pressure switch-indication shows on the HYDRAULIC synoptic page (HSP) of the Engine Indication and Crew Alerting System (EICAS).
Possible Causes:
- Data Acquisition Unit (DAU) 1 (A17)
- Data Acquisition Unit (DAU) 2 (A18)
- Data Acquisition Unit (DAU) 3 (A30)
- Data Acquisition Unit (DAU) 4 (A31)
- Engine-Driven Hydraulic Pump (EDP) 1A Pressure-Switch (S34)
- Engine-Driven Hydraulic Pump (EDP) 2A Pressure-Switch (S37)
- AC Motor Pump (ACMP) 1B Pressure-Switch (S36)
- AC Motor Pump (ACMP) 2B Pressure-Switch (S38)
- AC Motor Pump (ACMP) 3A Pressure-Switch (S39)
- AC Motor Pump (ACMP) 3B Pressure-Switch (S40)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Opening of Non-Thermal Circuit Breakers | AMM 24-00-00-863-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of Non-Thermal Circuit Breakers | AMM 24-00-00-863-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Hydraulic Safety Precautions | AMM 29-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Hydraulic Technical Precautions | AMM 29-00-00-910-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Pressurize the No. 1 and No. 2 Hydraulic Systems | AMM 29-10-00-862-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Release Hydraulic Pressure - No. 1 and No. 2 Hydraulic Systems | AMM 29-10-00-862-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Pressurize the No. 3 Hydraulic System | AMM 29-10-00-862-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Release Hydraulic Pressure - No. 3 Hydraulic System | AMM 29-10-00-862-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the External Avionics-Compartment Access-Panel (140BB) | AMM 52-45-11-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the External Avionics-Compartment Access-Panel (140BB) | AMM 52-45-11-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Start the Engine | AMM 71-00-00-866-806 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Engine Shutdown (Usual) | AMM 71-00-00-866-809 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Display the HYDRAULIC synoptic page (HSP) on the EICAS.
- Release the pressure from the related hydraulic-system. Check if the hydraulic pump flow-lines between the systems EDP and/or ACMPs and the PSI indication are green.
- If the flow-lines are not green, do close out.
- If the flow-lines are green, continue with the next step.
- Pressurize the affected hydraulic-system 1, hydraulic-system 2 or hydraulic-system 3. Check if the hydraulic pump flow-lines between the systems EDP and/or ACMPs and the PSI indication are green.
- If the flow-lines are green, do close out.
- If the flow-lines are not green, release the pressure from the affected hydraulic-system and continue with next step.
- Check which of the following switches show HIGH or LOW indication:
- If it is ACMP 1B (B PUMP) pressure-switch (HIGH or LOW) indication, go to step 7.
- If it is EDP 2A (A PUMP) pressure-switch (HIGH or LOW) indication, go to step 9.
- If it is ACMP 2B (B PUMP) pressure-switch (HIGH or LOW) indication, go to step 11.
- If it is ACMP 3A (A PUMP) pressure-switch (HIGH or LOW) indication, go to step 13.
- If it is ACMP 3B (B PUMP) pressure-switch (HIGH or LOW) indication, go to step 15.
- If it is EDP 1A (A PUMP) pressure-switch (HIGH or LOW) indication, continue with next step.
- Remove the DAU 2 to get access to connector A18BP1 and disconnect the connector S34P1 from the EDP 1A hydraulic pressure-switch. Perform a voltage check as follows:
From To Expected Result Result S34P1-B Ground 11±1 VDC - If there is 11±1 VDC, perform troubleshooting of EDP 1A HYDRAULIC PRESSURE SWITCHES FAULT CONDITION SENSED and do close out.
- If there is no 11±1 VDC, continue with next step.
- Perform a continuity check for an open circuit or a short circuit to ground between EDP 1A connector (S34P1) and DAU 2 connector (A18BP1) as follows:
From To Result S34P1-B A18BP1-E4 S34P1-A Ground - If there is a short circuit to ground or an open circuit, repair or replace the defective wiring as required. Connect the disconnected connectors and do close out.
- If there is no short circuit to ground or an open circuit, connect the disconnected connectors and perform the troubleshooting for observed fault DAU 2A (2B) FAIL.
- Remove the DAU 2 to get access to connector A18BP1 and disconnect the connector S36P1 from the ACMP 1B hydraulic pressure-switch. Perform a voltage check as follows:
From To Expected Result Result S36P1-B Ground 11±1 VDC - If there is 11±1 VDC, perform troubleshooting of ACMP 1A HYDRAULIC PRESSURE SWITCHES FAULT CONDITION SENSED and do close out.
- If there is no 11±1 VDC, continue with next step.
- Perform a continuity check for an open circuit or a short circuit to ground between ACMP 1B connector (S36P1) and DAU 2 connector (A18BP1) as follows:
From To Result S36P1-B A18BP1-H11 S36P1-A Ground - If there is a short circuit to ground or an open circuit, repair or replace defective wiring as required. Connect the disconnected connector and do close out.
- If there is no short circuit to ground or an open circuit, connect the disconnected connector and perform the troubleshooting for observed fault DAU 2A (2B) FAIL.
- Remove the DAU 3 to get access to connector A30BP1 and disconnect the connector S37P1 from the EDP 2A hydraulic pressure-switch. Perform a voltage check as follows:
From To Expected Result Result S37P1-B Ground 11±1 VDC - If there is 11±1 VDC, perform troubleshooting of EDP 2A HYDRAULIC PRESSURE SWITCHES FAULT CONDITION SENSED and do close out.
- If there is no 11±1 VDC, continue with next step.
- Perform a continuity check for an open circuit or a short circuit to ground between EDP 2A connector (S37P1) and DAU 3 connector (A30BP1) as follows:
From To Result S37P1-B A30BP1-E4 S37P1-A Ground - If there is a short circuit to ground or an open circuit, repair or replace defective wiring as required. Connect the disconnected connector and do close out.
- If there is no short circuit to ground or an open circuit, connect the disconnected connector. Perform the troubleshooting for observed fault DAU 3A (3B) FAIL and do close out.
- Remove the DAU 3 to get access to connector A30BP1 and disconnect the connector S38P1 from the ACMP 2B hydraulic pressure-switch. Perform a voltage check as follows:
From To Expected Result Result S38P1-B Ground 11±1 VDC - If there is 11±1 VDC, perform troubleshooting of ACMP 2B HYDRAULIC PRESSURE SWITCHES FAULT CONDITION SENSED and do close out.
- If there is no 11±1 VDC, continue with next step.
- Perform a continuity check for an open circuit or a short circuit to ground between ACMP 2B connector (S38P1) and DAU 3 connector (A30BP1) as follows:
From To Result S38P1-B A30BP1-H11 S38P1-A Ground - If there is a short circuit to ground or an open circuit, repair or replace the defective wiring. Connect the disconnected connector and do close out.
- If there is no short circuit to ground or an open circuit, connect the disconnected connector. Perform the troubleshooting for observed fault DAU 3A (3B) FAIL.
- Remove the DAU 4 to get access to connector A31BP1 and disconnect the connector S39P1 from the ACMP 3A hydraulic pressure-switch. Perform a voltage check as follows:
From To Expected Result Result S39P1-B Ground 11±1VDC - If there is 11±1 VDC, perform troubleshooting of ACMP 3A HYDRAULIC PRESSURE SWITCHES FAULT CONDITION SENSED and do close out.
- If there is no 11±1 VDC, continue with next step.
- Perform a continuity check for an open circuit or a short circuit to ground between ACMP 3A connector (S39P1) and DAU 4 connector (A31BP1) as follows:
From To Result S39P1-B A31BP1-E4 S39P1-A Ground - If there is a short circuit to ground or an open circuit, repair or replace the defective wiring. Connect the disconnected connector and do close out.
- If there is no short circuit to ground or an open circuit, connect the disconnected connector. Perform the troubleshooting for observed fault DAU 4A (4B) FAIL.
- Remove the DAU 4 to get access to connector A31BP1 and disconnect the connector S40P1 from the ACMP 3A hydraulic pressure-switch. Perform a voltage check as follows:
From To Expected Result Result S40P1-B Ground 11±1 VDC - If there is 11±1 VDC, perform troubleshooting of ACMP 3B HYDRAULIC PRESSURE SWITCHES FAULT CONDITION SENSED and do close out.
- If there is no 11±1 VDC, continue with next step.
- Perform a continuity check for an open circuit or a short circuit to ground between between ACMP 3B connector (S40P1) and DAU 4 connector (A31BP1) as follows:
From To Result S40P1-B A31BP1-H11 S40P1-A Ground - If there is a short circuit to ground or an open circuit, repair or replace the defective wiring. Connect the disconnected connector and do close out.
- If there is no short circuit to ground or an open circuit, connect the disconnected connectors. Perform the troubleshooting for observed fault DAU 4A (4B) FAIL.
- Do close out.