Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/30/21

Message Overview:

Message Name:

AUTO SHUT-OFF BOXES DO NOT TURN THE LIGHTS OFF

Message Code: 333OBS004
Effectivity: All
System: Service Compartment Lighting System
System Description: 33-31-00
Schematic Diagram: 33-31-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 33-31-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

All the Lights in a Service Compartment do not come ON, or all the Lights in a Service Compartment do not turn off.

Possible Causes:

  • Left Auto-Shutoff Box (A186)
  • Auto-Shutoff Box (A189)
  • Mid Auto-Shutoff Box (A277)
  • Light Switch
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Operational Test of the Forward Maintenance Lights AMM 33-31-00-710-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Operational Test of the Aft Maintenance Lights AMM 33-31-00-710-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Auto-Shutoff Box AMM 33-31-17-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Auto-Shutoff Box AMM 33-31-17-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Standard Practices - System Description SPM 20-00-00-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap the service light switch. Check if the problem is corrected.
    NOTE: This makes sure the light switch is not the cause of the problem.

    1. If YES, replace the defective light switch and do close out.
    2. If NO, continue with the next step.

  2. Perform a continuity check between auto-shutoff box and all the light switches ground in ON position as follows:

    From To Result
    A186P1-C Ground
    A189P1-C Ground

    1. If there is continuity, repair or replace the defective wiring as required and continue with the next step.
    2. If there is no continuity, continue with the next step.

  3. Disconnect the output wires of the auto-shutoff box connectors (A186J/P1 and A189J/P1) and perform a 28 VDC voltage check at the connectors as follows:

    From To Result
    A186J1-E Ground
    A189J1-E Ground

    1. If there is output voltage from the auto-shutoff box, repair or replace defective wiring as required and do close out.
    2. If there is no output voltage, continue with the next step.

  4. Measure the input voltage at the connectors for forward auto-shutoff box (A186) and rear auto-shutoff box (A189) as follows:

    From To Result
    A186P1-A A186P1-B
    A189P1-A A189P1-B

    1. If there is no voltage, repair or replace the defective wiring as required and do close out.
    2. If there is input voltage to the box, continue with the next step.

  5. Replace the unserviceable Auto-Shutoff Box.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  6. Perform the troubleshooting for CAS Message "ELEC SYS FAIL" (Amber) and "ELEC SYS FAULT" (Cyan).
  7. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.