06/30/21
Message Overview:
Message Name:
LOGO LIGHTS UNSERVICEABLE
| Message Code: | 334OBS009 |
| Effectivity: | Post SB 700-33-001 |
| System: | Logo Lighting System |
| System Description: | 33-46-00 |
| Schematic Diagram: | 33-46-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 33-46-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
Logo Light or Lights do not come ON.
Possible Causes:
- External Lights Control Panel (AP11)
- Logo Light Bulb
- Left Logo Light (DS62)
- Right Logo Light (DS63)
- Logo Light Switch
- Logo Light Assembly
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- SB 700-33-001 - Logo Lighting - Addition of Logo Lights
- SB 700-24-045 - Modification - AC and DC Power Distribution - Unit Change and Activation of Build 4 Electrical System
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Opening of Non-Thermal Circuit Breakers | AMM 24-00-00-863-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of Non-Thermal Circuit Breakers | AMM 24-00-00-863-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the EXTERNAL LIGHTS Control Panel | AMM 33-40-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the EXTERNAL LIGHTS Control Panel | AMM 33-40-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Logo Lighting | AMM 33-46-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Logo Lights | AMM 33-46-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Logo Lights | AMM 33-46-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Replacement of the Logo Light Bulb | AMM 33-46-01-960-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
On A/C 9002 to 9122 Pre SB 700-24-045:
- Set the LOGO switch to ON.
- If both logo lights do not operate, perform the troubleshooting for LOGO LIGHTING TRANSFORMER UNSERVICEABLE and continue with next step.
- If only one logo light does not operate, continue with next step.
- Disconnect the connectors (DS62P1) for the left logo light (DS62) and (DS63P1) for the right logo light (DS63). Perform a voltage check at the connectors as follows:
For the left logo light (DS62):From To Expected Result Result DS62P1-A DS62P1-B 28 VDC For the right logo light (DS63):
From To Expected Result Result DS63P1-A DS63P1-B 28 VDC - If there is voltage, go to step 5.
- If there is no voltage, continue with next step.
- Replace logo light bulb.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace logo light assembly.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Disconnect the connector A48J1 and measure the voltage at the connector A48J1 that follow:
For the Left Logo Light, Between APU Starter-Contactor Connector (A48J1):From To Expected Result Result A48J1-M A48J1-P 28 VAC For the Right Logo Light, Between APU Starter-Contactor Connector (A48J1):
From To Expected Result Result A48J1-N A48J1-R 28 VAC - If there is voltage, repair the defective wiring as required and go to step 7.
- If there is no voltage, continue with next step.
- perform the troubleshooting for LOGO LIGHTING TRANSFORMER UNSERVICEABLE and continue with next step.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform the troubleshooting for CAS Message listed below:
- Do close out.
On A/C 9123 and subs and Post SB 700-24-045:
- Set the LOGO switch to ON.
- If both logo lights do not operate, replace the external lights control panel and do close out.
- If only one logo light does not operate, continue with next step.
- Disconnect the connectors (DS62P1) for the left logo light (DS62) and (DS63P1) for the right logo light (DS63). Perform a voltage check at the connectors that follow:
For the left logo light (DS62):From To Expected Result Result DS62P1-A DS62P1-B 28 VDC For the right logo light (DS63):
From To Expected Result Result DS63P1-A DS63P1-B 28 VDC - If there is no voltage, repair the defective wiring as required and do close out.
- If there is voltage, continue with next step.
- Replace logo light bulb.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace logo light assembly.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform the troubleshooting for CAS Message listed below:
- Do close out.