07/01/21
Message Overview:
Message Name:
GPWS FLAP OVERRIDE FUNCTION FAIL
| Message Code: | 344OBS004 |
| Effectivity: | All |
| System: | Enhanced Ground Proximity Warning-System (EGPWS) |
| System Description: | 34-42-00 |
| Schematic Diagram: | 34-42-00 [ Global Express ] [ G5000 ] [ GlobalXRS ] |
| Wiring Diagram: | 31-43-01 [ Global Express ] [ G5000 ] [ Global XRS ] 34-42-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The flap override function of the Ground Proximity Warning-System (GPWS) is not operational. The aural warning “LANDING FLAPS” continues after the FLAP OVRD Switch on the Enhanced Ground Proximity Warning-System (EGPWS) Control Panel is set to ON.
Possible Causes:
- Enhanced Ground Proximity Warning-System (EGPWS) Control Panel (AP72)
- Ground Proximity Warning-System (GPWS) Computer (A64)
- Data Acquisition Unit (DAU) 1 (A17)
- Lamp Dimmer Power Supply (LDPS) 2 (A146)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter:
- EGPWS Mode 6 Altitude Callout - Navigation - EGPWS - Configuration Strapping for Alternate Mode 6 Aural Altitude Callouts
Normal operation of Flap override can be tested by going to the system diagnostics page and do the SELF TEST LEVEL 6 for the GPWS on PMAT (AMM TASK 45-45-00-970-804). The follows will happen:
- "LANDING FLAPS" will be heard from the flight compartment speakers when FLAP OVRD switch is set to ON
- "NOT LANDING FLAPS" will be heard when FLAP OVRD switch is set to OFF
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Data Acquisition System | AMM 31-42-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Lamp-Dimmer Power-Supply System | AMM 31-43-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Lamp-Dimmer Power Supplies | AMM 31-43-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Lamp-Dimmer Power Supplies | AMM 31-43-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Enhanced Ground-Proximity Warning System (EGPWS) |
AMM 34-42-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Enhanced Ground-Proximity Warning System (EGPWS) Computer |
AMM 34-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Enhanced Ground-Proximity Warning System (EGPWS) Computer |
AMM 34-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the EGPWS Control Panel | AMM 34-42-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the EGPWS Control Panel | AMM 34-42-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the EGPWS Control Panel | AMM 34-42-05-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove the DAU 1 to get access to the connector A17AP1, electrical connector A146P1 from the lamp-dimmer power supply 2, EGPWS control panel connector (AP72P1) and GPWS computer connector (A64BP1). Perform a continuity check between the connectors that follows:
From To Result AP72P1-V A146P1-C AP72P1-U GS1024 AP72P1-N A17AP1-A7 AP72P1-R A64BP1-C9 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Install the DAU 1 and perform the operational test.
- If the results of the operational test are not satisfactory, perform the troubleshooting for CAS message DAU 1A FAIL (Advisory) or DAU 1B FAIL (Advisory).
- If the results of the operational test are satisfactory, continue with the next step.
- Connect the disconnected electrical connector A146P1 to the lamp-dimmer power supply 2. Perform the operational test of the lamp-dimmer power supply 2.
- If the results of the operational test are not satisfactory, perform troubleshooting for Panel Integral Lighting and do close out.
- If the results of the operational test are satisfactory, continue with next step.
- Connect the disconnected connector A64BP1 and perform the operational test of the GPWS computer.
- If the results of the operational test are not satisfactory, perform the troubleshooting for CAS message GPWS SYSTEMS FAIL (Advisory) and do close out.
- If the results of the operational test are satisfactory, continue with next step.
- Replace EGPWS control panel.
- Do close out.