Message Overview:
Message Description:
Auxiliary Power Center Primary Logic (PCB11) has failed.
Possible Causes:
- Auxiliary Power Center Primary Logic (ALOG) (PCB11)
- Auxiliary Generator Power-Module (AGPM) (PCB10)
- Auxiliary Generator Control-Unit (AGCU) (PCB9)
- Auxiliary Power Unit (APU) Electronic Control Unit (ECU) (A39)
- Auxiliary DC Power Center (AUX DCPC) (A196)
- APU Generator (G3)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-24-0023 - Nuisance "ELECTRICAL FAULT" CAS Message During APU Start
- AW300-24-0024 - Electrical System - Troubleshooting Tips
- AW300-24-0137 - Y06 Electrical System Upgrade
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the APU Generator | AMM 24-31-09-000-801 |
| Installation of the APU Generator | AMM 24-31-09-400-801 |
| Removal of the Generator Control Unit (GCU) - Primary | AMM 24-31-13-000-801 |
| Installation of the Generator Control Unit (GCU) - primary | AMM 24-31-13-400-801 |
| Removal of the Auxiliary Generator Control-Unit | AMM 24-31-17-000-801 |
| Installation of the Auxiliary Generator Control-Unit | AMM 24-31-17-400-801 |
| Removal of the Generator Power Module | AMM 24-31-21-000-801 |
| Installation of the Generator Power Module | AMM 24-31-21-400-801 |
| Removal of the Auxiliary Generator Power-Module | AMM 24-31-25-000-801 |
| Installation of the Auxiliary Generator Power-Module | AMM 24-31-25-400-801 |
| Removal of the Auxiliary DC Power Center (Aux DCPC) | AMM 24-64-01-000-801 |
| Installation of the Auxiliary DC Power Center (Aux DCPC) | AMM 24-64-01-400-801 |
| Removal of the Auxiliary Power Center Primary-Logic | AMM 24-64-13-000-801 |
| Installation of the Auxiliary Power Center Primary-Logic | AMM 24-64-13-400-801 |
| Removal of the Auxiliary Power Unit (APU) Electronic Control Unit (ECU) | AMM 49-61-01-000-801 |
| Installation of the Auxiliary Power Unit (APU) Electronic Control Unit (ECU) | AMM 49-61-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Remove the Auxiliary Generator Power-Module PCB10. Inspect the card and connector. If no damage is found, reinstall the card making sure it is fully and properly inserted into place. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Swap the Auxiliary Generator Power-Module PCB10 with the Right Generator Power Module PCB8 or the Left Generator Power Module PCB7. Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Auxiliary Generator Power-Module.
- Swap the Auxiliary Generator Control-Unit PCB9 with the Right Generator Control Unit PCB6 or the Left Generator Control Unit PCB5. Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Auxiliary Generator Control-Unit.
- Do wiring check of the following wires:
From To Result APU ECU conn. A39AP1 - pin 6A AUX DCPC conn. A196P1 - pin L APU ECU conn. A39AP1 - pin 7A Ground Stud GS4013 APU ECU conn. A39BP1 - pin 1B AUX DCPC conn. A196P1 - pin Y APU ECU conn. A39BP1 - pin 3B AUX DCPC conn. A196P1 - pin S - If wiring check is satisfying, continue with next step.
- If wiring check is not satisfying, repair the defective wire.
- Do wiring check of the following wires:
From To Result APU GEN conn. G3P1 - pin A AUX DCPC conn. A196P1 - pin G APU GEN conn. G3P1 - pin B AUX DCPC conn. A196P1 - pin F APU GEN conn. G3P1 - pin D AUX DCPC conn. A196P1 - pin K APU GEN conn. G3P1 - pin F AUX DCPC conn. A196P1 - pin h APU GEN conn. G3P1 - pin E AUX DCPC conn. A196P1 - pin H APU GEN conn. G3P1 - pin G AUX DCPC conn. A196P1 - pin AA APU GEN conn. G3P1 - pin L AUX DCPC conn. A196P1 - pin JJ APU GEN conn. G3P1 - pin M AUX DCPC conn. A196P1 - pin z APU GEN conn. G3P1 - pin H AUX DCPC conn. A196P1 - pin D APU GEN conn. G3P1 - pin J AUX DCPC conn. A196P1 - pin d APU GEN conn. G3P1 - pin K AUX DCPC conn. A196P1 - pin E - If wiring check is satisfying, continue with next step.
- If wiring check is not satisfying, repair the defective wire.
- Replace the Auxiliary Power Center Primary Logic PCB11. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the Auxiliary Power Unit (APU) Electronic Control Unit (ECU). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective APU ECU.
- Replace the AUX DCPC. Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective AUX DCPC.
- Replace the APU Generator.
- Do close out.