11/21/25
Message Overview:
Message Name:
[CPC1] OUTFLOW VALVE #2
Message Code:
2137316ABG
Associated CAS:
| Reporting LRU: | Cabin Pressure Controller 1 |
| System Description: | 21-31-00- Cabin Pressure Control System |
| Schematic Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 21-31-00 Cabin Pressure Control System |
| Wiring Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 21-31-0 3 Cabin Pressure Control System |
Message Description:
During PBIT, the OFV2 does not respond to test command from CPC1.
Possible Causes:
- Cabin Pressure Controller 1 (CPC1) (A21)
- Aft Outflow Valve 2 (OFV2) (L9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None: None
NOTES:
- CPC in control alternate between CPC 1 and CPC 2
- CPC1 is used for odd days.
- CPC2 is used for even days.
Quick Links:
| Removal of the Cabin Pressure Controllers | AMM 21-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Cabin Pressure Controllers | AMM 21-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Outflow Valves | AMM 21-31-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Outflow Valves | AMM 21-31-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Initiate an IBIT from CPC1. (CPC1 is used for odd days. CPC2 is used for even days). If test passes with CPC1, Interchange CPC1 and CPC2. If problem follows, replace the defective LRU.
- Perform wiring checks between CPC1 (A21P1) and Outflow Valve 2 as follows:
From To Result A21P1-39 L9P1-10 A21P1-46 L9P1-13 A21P1-31 L9P1-11 A21P1-38 L9P1-14 A21P1-25 L9P1-12 NOTE: Make sure to also check for short circuit to ground on these conductors.
- If there is continuity, continue with next step.
- If there is no continuity, repair defective wiring as required and do close out.
- Replace Outflow Valve 2.
- Do close out.