06/03/19
Message Overview:
Fault Message:
CPC1 [NO DATA] /OUTFLOW VALVE1 /WRG
Fault Code:
2137321ABG
Associated CAS:
| Reporting LRU: | Cabin Pressure Controller (CPC) 1 |
| System Description: | 21-31-00 |
| Schematic Diagram: | 21-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 21-31-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Cabin Pressure Controller (CPC) 1 does not receive the ARINC 422 signal from Outflow Valve (OFV) 1.
Possible Causes:
- Cabin Pressure Controller (CPC) 1 (A21)
- FWD Outflow Valve (OFV) 1 (L8)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Cabin Pressure Controllers | AMM 21-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Cabin Pressure Controllers | AMM 21-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Outflow Valves | AMM 21-31-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Outflow Valves | AMM 21-31-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks of the ARINC 422 (RX) wires going from OFV 1 to CPC 1.
- If wiring checks are not good, repair the defective associated wiring and do close out.
- If wiring checks are good, continue with next step.
- Swap CPC 1 with CPC 2.
- If system checks are good, replace the CPC 1 and do close out.
- If fault remains, continue with next step.
- Replace OFV#1.
- Do close out.