Message Overview:
Message Name:
[CPC2] OUTFLOW VALVE #1
Message Code:
2138317ABG
Associated CAS:
| Reporting LRU: | Cabin Pressure Controller (CPC) 2 |
| System Description: | 21-31-00 - Cabin Pressure Control System |
| Schematic Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 21-31-00 Cabin Pressure Control System |
| Wiring Diagram: | [ Global Express ] [ G5000 ] [ Global XRS ] 21-31-04 Cabin Pressure Control System |
Message Description:
During Power-On Built-in Test (PBIT), the Outflow Valve (OFV) 1 does not respond to test command from Cabin Pressure Controller (CPC) 2.
Possible Causes:
- Outflow Valve 1 (L8)
- Cabin Pressure Controller (CPC) 2 (A22)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None None
NOTES:
- CPC in control alternates between CPC 1 and CPC 2
- CPC1 is used for odd days.
- CPC2 is used for even days.
Quick Links:
| Removal of the Outflow Valves | AMM 21-31-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Outflow Valves | AMM 21-31-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Initiate an IBIT from CPC2. (CPC1 is used for odd days. CPC2 is used for even days). If test passes with CPC1, Interchange CPC2 and CPC1. If problem follows, replace the defective LRU.
- Perform wiring check of the OFV 1 grounds.
- If YES, continue with next step.
- If NO, replace Cabin Pressure Controller (CPC) 2 and do close out.
- Replace OFV#1.
- Do close out.