Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/03/19

Message Overview:

Fault Message:

OUTFLOW VALVE 2 [NO DATA]/CPC2 /WRG

Fault Code:

2138318ABG

Associated CAS:

AUTO PRESS FAIL
(Caution)

AUTO PRESS FAULT
(Advisory)

OUTFLOW VLV 2 FAIL
(Advisory)

Reporting LRU: Cabin Pressure Controller (CPC) 2
System Description: 21-31-00
Schematic Diagram: 21-31-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-31-04 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Outflow Valve (OFV) 2 does not receive the ARINC 422 signal from Cabin Pressure Controller (CPC) 2.

Possible Causes:

  • Outflow Valve (OFV) 2 (L9)
  • Cabin Pressure Controller (CPC) 2 (A22)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Cabin Pressure Controllers AMM 21-31-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Cabin Pressure Controllers AMM 21-31-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Outflow Valves AMM 21-31-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Outflow Valves AMM 21-31-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Perform wiring check of the ARINC 422 (TX) wires going from CPC2 to OFV2.

    1. If wiring check is good, continue with next step.
    2. If wiring check is not good, repair defective associated wiring as required and do close out.

  2. Swap CPC2 with CPC1. Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace Cabin Pressure Controller (CPC) 2 and do close out.

  3. Replace OFV2.
  4. Do close out.