Message Overview:
Fault Message:
CPC2 [NO DATA] /DAU4 [CH B] /WRG
Fault Code:
2138327ABG
Associated CAS:
| Reporting LRU: | Cabin Pressure Controller (CPC) 2 |
| System Description: | 21-31-00 |
| Schematic Diagram: | 21-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-42-08 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Cabin Pressure Controller (CPC) 2 does not receive the ARINC 429 signal from Data Acquisition Unit (DAU) 4B.
Possible Causes:
- Cabin Pressure Controller (CPC) 2 (A22)
- Data Acquisition Unit (DAU) 4 (A31)
- Data Acquisition Unit (DAU) 4 Channel B
- Junction Box (JB4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Cabin Pressure Controllers | AMM 21-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Cabin Pressure Controllers | AMM 21-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB4 | AMM 24-00-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 | AMM 24-00-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10 [ Global Express ] [G5000 ] [Global XRS ] |
Troubleshooting Recommendations:
- Swap DAU 4 with DAU 3.
- If system checks are good, replace DAU 4 and do close out.
- If fault remains, continue with next step.
- Swap CPC 2 with CPC 1.
- If system checks are good, replace CPC 2 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks of the wires between CPC2 and JB4.
- If wiring checks are good, continue with next step.
- If wiring checks are not good, repair defective associated wiring and do close out.
- Perform wiring checks of the wires between JB4 and DAU4.
- If wiring checks are good, continue with next step.
- If wiring checks are not good, repair defective associated wiring and do close out.
- Perform continuity check of JB4.
- If there is continuity, repair defective associated wiring and do close out.
- If there is no continuity, continue with next step.
- Replace JB4.
- Do close out.