Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

12/20/23

Message Overview:

Message Name:

CABIN PRESSURE CONTROLLER #2

Message Code:

2138329ABG

Associated CAS:

AUTO PRESS FAIL
(Caution)

AUTO PRESS FAULT
(Advisory)

MAN PRESS FAULT
(Advisory)

Reporting LRU: Cabin Pressure Controller (CPC) 2
System Description: 21-31-00 - Cabin-Pressure Control System
Schematic Diagram: [ Global Express ]  [ G5000 ]  [ Global XRS ] SSM 21-31-00-101 - Cabin-Pressure Control System
Wiring Diagram: [ Global Express ]  [ G5000 ]  [ Global XRS ] WM 21-31-00-02 - Cabin Pressure Control System - Controller Right - 9003-9011-9158
[ Global Express ]  [ G5000 ]  [ Global XRS ] WM 21-31-00-01 - Cabin Pressure Control System - Controller Right - 9004-9010
[ Global Express ]  [ G5000 ]  [ Global XRS ] WM 21-31-00-03 - Cabin Pressure Control System - Controller Right - 9002

Message Description:

An internal failure has been detected in Cabin Pressure Controller (CPC) 2.

Possible Causes:

  • Cabin Pressure Controller (CPC) 2 (A22)
  • Cabin Pressure Controller (CPC) 1 (A21)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Flight Operation Notifications Manual (FONM): None

Quick Links:

Standard Aircraft Configuration for Maintenance [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM12-00-00-867-801
Aircraft Walkaround (for Maintenance) [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM12-00-00-867-802
Removal of the Cabin Pressure Controllers [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-31-01-000-801
Installation of the Cabin Pressure Controllers [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-31-01-400-801
Operational Test of the Cabin-Pressure-Controller Pressure Sensors [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM21-31-01-710-801
Connect Electrical Power to the Aircraft [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-861-801
Electrical/Electronic Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-801
Electrostatic Discharge Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-802
CAIMS PMAT General Instructions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM45-45-00-970-801
Access to Active Faults [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM45-45-00-970-802
Access to Stored Faults [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM45-45-00-970-803
Access to System Diagnostics [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM45-45-00-970-804

Troubleshooting Recommendations:

  1. Interchange CPC 2 with CPC 1. Does the fault clear?

    1. If YES, replace defective CPC and do close out.
    2. If NO, power-up each CPC one at the time and see if it generates a DELTA P (Warning).
    3. Replace the CPC that generates the CABIN DELTA P (Warning) and do close out.

  2. Normalize the CPC position, check for CABIN DELTA P (Warning), select MAN and then back to AUTO PRESS, make sure the fault is not present.
  3. Reselect the MAN and then back to AUTO PRESS again , make sure the fault is not present.
  4. Do close out.