Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/26/19

Message Overview:

Fault Message:

SLAT PDU

Fault Code:

2750018STD

Associated CAS:

SLAT FAIL
(Caution)

SLAT FAULT
(Caution)

SLAT FLAP FAIL
(Caution)

SLAT FLAP FAULT
(Caution)

SLAT FLAP HALFSPD
(Advisory)

SLAT HALFSPD
(Advisory)

Reporting LRU: Slat/Flap Control Unit (SFCU)
System Description: 27-53-00
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-07 [ Global Express ]  [ G5000 ]  [ Global XRS ]
27-50-08 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Slat/Flap Control Units (SFCUs) reporting the output of the Slat Power Drive Unit (PDU) Motor is too slow, too fast, or a Motor Brake has failed.

Possible Causes:

  • Slat/Flap Control Unit (SFCU) 1 (A124)
  • Slat/Flap Control Unit (SFCU) 2 (A95)
  • Slat Power Drive Unit (PDU) Motor 1 (B14)
  • Slat Power Drive Unit (PDU) Motor 2 (B13)
  • Slat Power Drive Unit (PDU)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW700-27-0373 - SFCU -17: “SLAT-FLAP HALFSPD” EICAS Nuisance Message

Forum Articles/Infoservice/Newsletter: None

  • Performing a SLAT FLAP RESET on the EMS CDU may clear this fault
    NOTE: Wait at least one minute after SFCU reset to allow self test to run.
  • Moving the SFCL to another detent may also clear this fault
  • Performing the CAIMS latched fault clear may also clear this fault

Quick Links:

Clear Slat/Flap Control Unit (SFCU) Latched Faults AMM 27-51-05-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Torque/Backlash Check of the Slat System AMM 27-53-00-820-805 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Slat Power-Drive Unit (PDU) AMM 27-53-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat Power-Drive Unit (PDU) AMM 27-53-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Slat Power-Drive Unit (PDU) Motors AMM 27-53-37-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat Power-Drive Unit (PDU) Motors AMM 27-53-37-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

Access CAIMS- active faults to see if one or both SFCUs are reporting the problem.

Fault reported by only one SFCU:

  1. Swap SFCUs.

    1. If system checks are good, replace defective SFCU and do close out.
    2. If fault remains, continue with next step.
      NOTE: If necessary perform the clear latched fault after swapping the SFCU.

  2. Swap Slat PDU motors.

    1. If system checks are good, replace defective slat PDU motor and do close out.
    2. If fault remains, continue with next step.

  3. Perform wiring checks from the SFCU racks as follow:

    Fault reported by the SFCU 1 (SLAT/FLAP CONTROL UNIT 1 STN 493 LHS):

    From To Resistance Range Result
    A124DP1-5 A124DP1-6 0.4050 to 0.2550 ohms
    A124DP1-6 A124DP1-1 0.4050 to 0.2550 ohms
    A124DP1-1 A124DP1-5 0.4050 to 0.2550 ohms
    A124AP1-10 A124AP1-12 9 to 11 ohms
    A124AP1-11 A124AP1-25 45.9 to 56.1 ohms
    A124AP1-24 A124AP1-25 45.9 to 56.1 ohms
    A124AP1-23 A124AP1-25 45.9 to 56.1 ohms

    Fault reported by the SFCU 2 (SLAT/FLAP CONTROL UNIT 2 STN 493 RHS):

    From To Resistance Range Result
    A95DP1-5 A95DP1-6 0.4050 to 0.2550 ohms
    A95DP1-6 A95DP1-1 0.4050 to 0.2550 ohms
    A95DP1-1 A95DP1-5 0.4050 to 0.2550 ohms
    A95AP1-10 A95AP1-12 9 to 11 ohms
    A95AP1-11 A95AP1-25 45.9 to 56.1 ohms
    A95AP1-24 A95AP1-25 45.9 to 56.1 ohms
    A95AP1-23 A95AP1-25 45.9 to 56.1 ohms

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  4. Perform torque/backlash check of the slat system.

    1. If check is normal, go to step 6.
    2. If there is friction or drag in the system, continue with next step.

  5. Repair mechanical defects.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  6. Replace slat PDU.
  7. Do close out.

Fault reported by both SFCUs:

  1. Energize AC and DC power of one SFCU to clear the latched fault.

    1. If latched fault is clear, go to step 3.
    2. If latched fault remains, continue with next step.

  2. Energize the other SFCU.

    1. If latched fault remains, go to step 5.
    2. If no latched fault remains, continue with next step.

  3. Operate at half speed by one SFCU only, and confirm if the slats can be operated at half speed by the same SFCU in the other position.

    1. If any SFCU cannot operate at half speed, go to step 5.
    2. If one SFCU can operate at half speed, swap SFCU.

      1. If slats can be operated at half speed by the same SFCU, do close out.
      2. If not, continue with next step.

  4. Swap slat PDU motor with any flap PDU motor to the SFCU that latched fault cannot be cleared.
    NOTE: SFCU 1=Slat PDU motor 1 (left), SFCU 2=Slat PDU motor 2 (right).

    1. If system checks are good, replace slat PDU motor and do close out.
    2. If fault remains, continue with next step.

  5. Perform torque/backlash check of the slat system.

    1. If check is normal, go to step 7.
    2. If there is friction or drag in the system, continue with next step.

  6. Repair mechanical defects.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  7. Replace slat PDU.
  8. Do close out.