06/26/19
Message Overview:
Fault Message:
SLAT PDU
Fault Code:
2750018STD
Associated CAS:
| Reporting LRU: | Slat/Flap Control Unit (SFCU) |
| System Description: | 27-53-00 |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-07 [ Global Express ] [ G5000 ] [ Global XRS ] 27-50-08 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Slat/Flap Control Units (SFCUs) reporting the output of the Slat Power Drive Unit (PDU) Motor is too slow, too fast, or a Motor Brake has failed.
Possible Causes:
- Slat/Flap Control Unit (SFCU) 1 (A124)
- Slat/Flap Control Unit (SFCU) 2 (A95)
- Slat Power Drive Unit (PDU) Motor 1 (B14)
- Slat Power Drive Unit (PDU) Motor 2 (B13)
- Slat Power Drive Unit (PDU)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-27-0373 - SFCU -17: “SLAT-FLAP HALFSPD” EICAS Nuisance Message
Forum Articles/Infoservice/Newsletter: None
- Performing a SLAT FLAP RESET on the EMS CDU may clear this fault
NOTE: Wait at least one minute after SFCU reset to allow self test to run. - Moving the SFCL to another detent may also clear this fault
- Performing the CAIMS latched fault clear may also clear this fault
Quick Links:
| Clear Slat/Flap Control Unit (SFCU) Latched Faults | AMM 27-51-05-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Torque/Backlash Check of the Slat System | AMM 27-53-00-820-805 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Slat Power-Drive Unit (PDU) | AMM 27-53-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat Power-Drive Unit (PDU) | AMM 27-53-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Slat Power-Drive Unit (PDU) Motors | AMM 27-53-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat Power-Drive Unit (PDU) Motors | AMM 27-53-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
Access CAIMS- active faults to see if one or both SFCUs are reporting the problem.
Fault reported by only one SFCU:
- Swap SFCUs.
- If system checks are good, replace defective SFCU and do close out.
- If fault remains, continue with next step.
NOTE: If necessary perform the clear latched fault after swapping the SFCU.
- Swap Slat PDU motors.
- If system checks are good, replace defective slat PDU motor and do close out.
- If fault remains, continue with next step.
- Perform wiring checks from the SFCU racks as follow:
Fault reported by the SFCU 1 (SLAT/FLAP CONTROL UNIT 1 STN 493 LHS):
From To Resistance Range Result A124DP1-5 A124DP1-6 0.4050 to 0.2550 ohms A124DP1-6 A124DP1-1 0.4050 to 0.2550 ohms A124DP1-1 A124DP1-5 0.4050 to 0.2550 ohms A124AP1-10 A124AP1-12 9 to 11 ohms A124AP1-11 A124AP1-25 45.9 to 56.1 ohms A124AP1-24 A124AP1-25 45.9 to 56.1 ohms A124AP1-23 A124AP1-25 45.9 to 56.1 ohms Fault reported by the SFCU 2 (SLAT/FLAP CONTROL UNIT 2 STN 493 RHS):
From To Resistance Range Result A95DP1-5 A95DP1-6 0.4050 to 0.2550 ohms A95DP1-6 A95DP1-1 0.4050 to 0.2550 ohms A95DP1-1 A95DP1-5 0.4050 to 0.2550 ohms A95AP1-10 A95AP1-12 9 to 11 ohms A95AP1-11 A95AP1-25 45.9 to 56.1 ohms A95AP1-24 A95AP1-25 45.9 to 56.1 ohms A95AP1-23 A95AP1-25 45.9 to 56.1 ohms - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform torque/backlash check of the slat system.
- If check is normal, go to step 6.
- If there is friction or drag in the system, continue with next step.
- Repair mechanical defects.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace slat PDU.
- Do close out.
Fault reported by both SFCUs:
- Energize AC and DC power of one SFCU to clear the latched fault.
- If latched fault is clear, go to step 3.
- If latched fault remains, continue with next step.
- Energize the other SFCU.
- If latched fault remains, go to step 5.
- If no latched fault remains, continue with next step.
- Operate at half speed by one SFCU only, and confirm if the slats can be operated at half speed by the same SFCU in the other position.
- If any SFCU cannot operate at half speed, go to step 5.
- If one SFCU can operate at half speed, swap SFCU.
- If slats can be operated at half speed by the same SFCU, do close out.
- If not, continue with next step.
- Swap slat PDU motor with any flap PDU motor to the SFCU that latched fault cannot be cleared.
NOTE: SFCU 1=Slat PDU motor 1 (left), SFCU 2=Slat PDU motor 2 (right).- If system checks are good, replace slat PDU motor and do close out.
- If fault remains, continue with next step.
- Perform torque/backlash check of the slat system.
- If check is normal, go to step 7.
- If there is friction or drag in the system, continue with next step.
- Repair mechanical defects.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace slat PDU.
- Do close out.