07/02/19
Message Overview:
Fault Message:
HEATSINK OVERTEMPERATURE #2
Fault Code:
2752044STD
Associated CAS:
| Reporting LRU: | Slat Flap Control Unit (SFCU) |
| System Description: | 27-51-00 |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-08 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Heat sink temperature of the Slat/Flap Motor Drive circuit in the Slat Flap Control Unit (SFCU) is more than 200°C (392°F) and the motor thermostat is open.
Possible Causes:
- Slat Flap Control Unit (SFCU) 1 (A124)
- Slat Flap Control Unit (SFCU) 2 (A95)
- Power Drive Unit (PDU) Motor
- Dragging Motor Brake
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- If there are other related active or stored faults, troubleshoot them first.
- On the EMS CDU, set the circuit breakers that follow to OUT for two or three seconds, and then set to IN:
System Name Circuit Breaker Bus Name FLT CONTROLS SLAT/FLAP CTLR 1 BATT FLT CONTROLS SLAT/FLAP CTLR 2 DC ESS - Set the selection to a new detent position on the slat/flap control handle and move the system to the new position. Perform this step four times, one after the other.
NOTE: Continuous duty must be limited to four cycles with an ambient temperature of 25 °C (76 °F).- If the fault message show again within four cycles, one after the other, let system become cool and go to step 6.
- If the fault message not shows within four cycles, continue with next step.
- Perform the rigging of the slat/flap control system.
- Set the selection a new detent position on the slat/flap control handle and move the system to the new position.
- If the fault not follows, go to step 7.
- If the fault follows, continue with next step.
- Swap SFCUs.
- If system checks are good, replace defective SFCU and do close out.
- If fault remains, continue with next step.
- If the fault message shows on the same channel set the EMS CDU circuit breakers that follow to OUT for two or three seconds, and then set to IN:
Sustem Name Circuit Breaker Bus Name FLT CONTROLS SLAT/FLAP CTLR 1 BATT FLT CONTROLS SLAT/FLAP CTLR 2 DC ESS - Set the selection to a new detent position on the slat/flap control handle and move the system to the new position. Perform this step four times, one after the other.
NOTE: Continuous duty must be limited to four cycles with an ambient temperature of 25 °C (76 °F).- If the fault message shows within four cycles, perform the fault isolation for CAIMS - SLAT MOTOR/ SFCU/ WRG and do close out.
- If the fault message does not show, continue with next step.
- Set the selection to a new detent position on the slat/flap control handle that moves only the flap system. Move the flap system to the new position. Perform this step four times, one after the other.
NOTE: Continuous duty must be limited to four cycles with an ambient temperature of 25 °C (76 °F).- If the fault message not shows within four cycles, do close out.
- If the fault message shows within four cycles, continue with next step.
- Perform the fault isolation for CAIMS - FLAP MOTOR/SFCU/WIRING.
- Do close out.