07/09/19
Message Overview:
Fault Message:
SLAT/FLAP CTRL UNIT #1/ WRG FAULT
Fault Code:
27661211SX
Associated CAS:
| Reporting LRU: | Flight Control Unit (FCU) 1 |
| System Description: | 27-50-00 |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-07 [ Global Express ] [ G5000 ] [ Global XRS ] 27-60-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Flight Control Unit (FCU) 1 does not receive the FLAP NOT ZERO signal from the Slat/Flap Control Unit 1 (SFCU 1).
Possible Causes:
- Slat/Flap Control Unit (SFCU) 1 (A124)
- Flight Control Unit (FCU) 1 (A65)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
This fault may sometime be cleared by performing the flight control system reset procedure.
Quick Links:
| Removal of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Flight-Control Units | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Flight-Control Units | AMM 27-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- If CAS message(s) or CAIMS fault(s) related to the Slat Control System is posted in addition to RUD LIMITER FAIL and SLAT/FLAP CTRL UNIT #1/WRG FAULT, troubleshoot the additional message(s) first.
- Swap SFCU 1 with SFCU 2.
- If system checks are good, replace SFCU 1 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between FCU 1 and SFCU 1 as follow:
From To Result A124AP1-94 A65FP1-1 - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace FCU 1 and reset FCUs latched faults.
- Do close out.