Message Overview:
Fault Message:
LH DC AUX PUMP/PRES SW/WRG
Fault Code:
2844611PK
Associated CAS:
| Reporting LRU: | Fuel Management and Quantity Gauging Computer (FMQGC) |
| System Description: | 28-21-00 |
| Schematic Diagram: | 28-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Left Auxiliary-Pump Pressure Indication is high and low at the same time.
Possible Causes:
- Left DC Auxiliary-Pump Pressure-Switch (S11)
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Opening of Non-Thermal Circuit Breakers | AMM 24-00-00-863-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of Non-Thermal Circuit Breakers | AMM 24-00-00-863-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Disconnect the Avionics Battery | AMM 24-32-00-040-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Connect the Avionics Battery | AMM 24-32-00-440-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Disconnect the APU Battery | AMM 24-32-00-040-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Connect the APU Battery | AMM 24-32-00-440-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Fuel-System Safety Precautions | AMM 28-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the DC Auxiliary Pumps | AMM 28-21-00-710-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Auxiliary-Pump Pressure-Switches | AMM 28-21-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Auxiliary-Pump Pressure-Switches | AMM 28-21-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Leading Edge Panels (BL52.45 to L/E STA 134.818) | AMM 57-41-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Leading Edge Panels (BL52.45 to L/E STA134.818) | AMM 57-41-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect connector S11P1 (LEFT AUX DC PUMP PRESS SW). Perform a continuity check on the pressure switch side as follows:
From To Result S11P1-G GS282 S11P1-A GS282 - If there is continuity, replace the left auxiliary-pump pressure-switch and do close out.
- If there is no continuity, continue with the next step.
- Remove the FMQGC. Perform a continuity check as follows:
From To Result A47AP1-D13 Ground A47DP1-E13 Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Re-rack the FMQGC making sure it is fully and properly inserted into place. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the FMQGC.
- Do close out.