Message Overview:
Fault Message:
LH DC AUX PUMP ELECT PWR/WRG
Fault Code:
2844612PK
Associated CAS:
| Reporting LRU: | Fuel Management and Quantity Gauging System (FMQGC) |
| System Description: | 28-22-00 |
| Schematic Diagram: | 28-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-22-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Left DC AUX PUMP failed ON or OFF due to:
- A failure of the Automatic Pump command signal from the Fuel Management and Quantity Gauging Computer (FMQGC) to the electrical system, OR
- A failure of the Manual Pump command signal from the Fuel Control Panel to the electrical system, OR
- A failure of the electrical system to power up or down the pump when commanded by the FMQGC or the Fuel Control Panel.
- A failure of the electrical system to provide pump power status feedback to the FMQGC.
Possible Causes:
- FUEL Control Panel (AP5)
- Junction Box (JB3)
- Junction Box (JB4)
- XFEED Shut Of Valve (SOV) Switch (SDS3)
- L WING FEED INHIBIT AUX PUMP Switch (SDS1)
- Electrical Management System Control-and-Display Units (EMS CDU) 1 (A94)
- Electrical Management System Control-and-Display Units (EMS CDU) 2 (A91)
- Secondary Power Distribution Assembly (SPDA) 2 (A14)
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB3 | AMM 24-00-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB3 | AMM 24-00-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB3 Circuit-Cards | AMM 24-00-02-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB3 Circuit-Cards | AMM 24-00-02-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB4 | AMM 24-00-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 | AMM 24-00-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB4 Circuit-Cards | AMM 24-00-06-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 Circuit-Cards | AMM 24-00-06-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Electrical Management System Control-and-Display Units (EMS CDU) | AMM 24-70-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Electrical Management System Control-and-Display Units (EMS CDU) | AMM 24-70-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Auxiliary-Pump Canisters | AMM 28-21-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Auxiliary-Pump Canister | AMM 28-21-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using CAIMS, verify if there is messages concerning the 28 VDC essential bus or SPDA are shown:
- If YES, troubleshoot them first.
- If NO, continue with next step.
- Select the SPDA 2A (2B) LOAD STATUS LABEL 046 (L AUX PUMP) page, via CAIMS. Set the left ENGINE RUN switch to ON, L AUX PUMPS switch/light to ON (Pushed out), and L PRIM PUMPS switch/light to OFF (Pushed in). Make sure the result that follows are met:
Reference Status LOGIC EQUATION STATE (L DC PUMP CMD) ON VIRTUAL CIRCUIT BREAKER (SSPC CIRCUIT BREAKER) IN VIRTUAL SWITCH (SSPC SW) ON LOCK STATE UNLOCKED VOLTAGE STATUS PRESENT CURRENT STATUS FLOWING TRIP STATUS (CIRCUIT BREAKER) NOT TRIP FAIL STATUS (SSPC) NOT FAILED - If the above status are met, go to step 20.
- If one of the above status is not met, go to step 4.
- If more than one status is not met, continue with next step.
- An alternative way of monitoring the result is to select ACPC IN via EMS CDU1 or CDU2 signboard Menu:
Left Column Center Column Label 046 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 1 1 1 1 1 1 X X X X X X X X Reference L AUX PUMP - Bit 22 :LOGIC EQUATION STATE (L DC PUMP CMD)
- Bit 23: VIRTUAL CIRCUIT BREAKER (SSPC CIRCUIT BREAKER)
- Bit 24: VIRTUAL SWITCH (SSPC SW)
- Bit 25: LOCK STATE
- Bit 26: VOLTAGE STATUS
- Bit 27: CURRENT STATUS
- Bit 28: TRIP STATUS (CIRCUIT BREAKER)
- Bit 29: FAIL STATUS (SSPC)
- If the above status are met, go to step 20.
- If one of the above status is not met, continue with next step.
- Perform wiring check (short to ground = fail) between the SPDA 2 (A14P4) and left wing auxiliary pump (B10P1). Repair as required.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform a ground check at left wing auxiliary pump (B10P1). Repair as required.
- If ground is not there, go to step 7.
- If ground is there, continue with next step.
- Swap the Auxiliary pump (B10P1).
- If system checks are good, replace defective Auxiliary pump and do close out.
- If fault remains continue with next step.
- On the SPDA 2A (B)-COMMUNICATION AND AIRCRAFT MODE page, via CAIMS, monitor the ARINC communication between EMS CDU and SPDA 2.
- If the CDU 1 ARINC COMM OK and CDU 2 ARINC COMM OK are shown as OK, go to step 20.
- If the CDU 2 ARINC COMM OK is shown as Bad, go to step 12.
- If the CDU 1 ARINC COMM OK is shown as Bad, go to step 9.
- If the both CDU 1 ARINC COMM OK and is CDU 2 ARINC COMM OK shown as Bad, continue with next step.
- An alternative way of monitoring the ARINC communication is to select SPDA 2 IN via EMS CDU 1 or CDU 2 Signboard Menu:
Center column Label 062 21 20 19 18 17 16 15 14 X X X X X 1 X 1 Reference SPDA 2 ARNIC Status - Bit 14 :CDU 1 ARINC COMM OK.
- Bit 16: CDU 2 ARINC COMM OK.
- If bit 14 and 16 are shown as 1, go to step 20.
- If bit 16 is shown as 0, go to step 12.
- If bit 14 is shown as 0, continue with next step.
- Perform wiring check via TP-63 between JB3/PCB3, SPDA 2 (A14P5), and EMS CDU 1 (A94P1). Repair as required.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring check via TP-64 between JB3/PCB3, SPDA 2 (A14P5), and EMS CDU 1 (A94P1). Repair as required.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace the JB3/PCB 3.
- If system checks are good, do close out.
- If fault remains, go to step 17.
- Perform wiring check via TP-33 between JB3/PCB2, JB4/PCB2, SPDA 2 (A14P6), and EMS CDU 2 (A91P1). Repair as required.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring check via TP-34 between JB3/PCB2, JB4/PCB2, SPDA 2 (A14P6), and EMS CDU 2 (A91P1). Repair as required.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace the JB3/PCB 2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the JB4/PCB 2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace JB4.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace JB3.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap the EMS CDUs.
- If system checks are good, replace defective EMS CDU and do close out.
- If fault remains, continue with next step.
- Swap the SPDA 2 with SPDA 1.
- If system checks are good, replace SPDA 2 and do close out.
- If fault remains, continue with next step.
- Replace FMQGC.
- Do close out.