08/05/19
Message Overview:
Fault Message:
FWC 3 - DISPLAY CONTROLLER FAULT
Fault Code:
3151008FW3
Associated CAS:
| Reporting LRU: | Multi-Function Display (MFD) |
| System Description: | 31-61-00 |
| Schematic Diagram: | 31-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] 31-61-05 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Two Multi-Function Display (MFD) Controllers have faults at the same time and cannot control the MFDs.
Possible Causes:
- Multi-Function Display (MFD) Controller 1 (A133)
- Multi-Function Display (MFD) Controller 2 (A134)
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Multi-Function Display (MFD) Control Panel | AMM 31-61-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Multi-Function Display (MFD) Control Panel | AMM 31-61-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Integrated Maintenance Test (IMT) Fault Code Look-Up | AMM 45-45-00-970-826 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check CAS message on EICAS display.
- If MFD CTLR 1 FAIL (Amber) appear, continue with next step.
- If MFD CTLR 2 FAIL (Amber) appear, go to step 3.
- If both MFD CTLR 1 FAIL and MFD CTLR 2 FAIL appear, go to step 4.
- Troubleshooting the fault accordance with MFD CTLR 1 FAIL.
- If fault remains, replace MFD controller 1 and do close out.
- If fault gone, do close out.
- Troubleshooting the fault accordance with MFD CTLR 2 FAIL.
- If fault remains, replace MFD controller 2 and do close out.
- If fault gone, do close out.
- Troubleshooting the fault accordance with MFD CTLR 1 FAIL and MFD CTLR 2 FAIL. Repair as required.
- Do close out.