Message Overview:
Fault Message:
WINDOW HEATER/WRG/EVSHC (OPEN)
Fault Code:
3000108IN
Associated CAS:
| Reporting LRU: | Enhanced Vision System Heater Controller (EVSHC) |
| System Description: | 34-33-00 |
| Schematic Diagram: | 34-33-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-33-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Enhanced Vision System (EVS) Infrared Window (IRW) Heating Film has been detected opened by the Enhanced Vision System Heater Controller (EVSHC).
Possible Causes:
- Infrared Window (IRW) (A320)
- Enhanced Vision System Heater Controller (EVSHC) (A315)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Enhanced Vision System (EVS) Infrared Window (IRW) |
AMM 34-33-06-000-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Enhanced Vision System (EVS) Infrared Window (IRW) |
AMM 34-33-06-400-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Enhanced Vision System (EVS) Heater Controller |
AMM 34-33-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Enhanced Vision System (EVS) Heater Controller |
AMM 34-33-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access and disconnect the EVS Heater Controller connector (A315P1) and the EVS Infrared Window connector (A320P1). Perform a wiring check as follows:
NOTE: Make sure to check for short circuit to ground and short circuit between wires.From To Result A315P1-KK A320J1-C A315P1-BB A320J1-G - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform a resistance check of the Infrared Window Heater using the EVSHC Troubleshooting Table.
NOTE: Nominal resistance between heater terminals is 44.08 Ω ±10%.- If the resistance value is out of range, replace the EVS Infrared Window (IRW) and do close out.
- If the resistance value is good, continue with next step.
- Replace the EVS Heater Controller (EVSHC).
- Do close out.