Message Overview:
Fault Message:
[BMC2] CROSSBLEED VALVE CMD /CBV
Fault Code:
3616318BMC
Associated CAS:
| Reporting LRU: | Bleed Management Controller (BMC) 2 |
| System Description: | 36-11-00 |
| Schematic Diagram: | 36-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-11-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Cross Bleed Valve position does not agree with the Bleed Management Controller (BMC) 2 command. Inhibited during Take-off and Landing.
Possible Causes:
- Cross Bleed Valve (CBV) (L35)
- Secondary-Power Distribution Assembly (SPDA) 3 (A15)
- Bleed Management Controller (BMC) 2 (A70)
- Junction Box (JB4)/PCB2
- Junction Box (JB4)/PCB3
- Relay (K15)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-36-0365 - Bleed management controller - Data Gathering to reduce No Fault Found (NFF) rate
- 700T-0006 - Revision 1 - WING A/ICE FAULT (Advisory) EICAS Messages
Forum Articles/Infoservice/Newsletter:
- Forum Article 2011-VOL 8 issue 23 - Bleed Management Controller (BMC) Top 10 No Fault Found (NFF) vs. Reliability Improvement Modification Program (RIMP) implementation
- Infoservice - Wing Anti-Ice Fault Spurious EICAS Messages (Dec/1999)
- Questionnaire for replacing the BMC. Follow instructions using this (Fill out form)
NOTE: Before removing JB4, replace PCB2 or PCB3 Circuit Card if available.
NOTE: Use spare relay if available.
NOTE: Always verify you are working with the current document revision. Access the CIC website to ensure the latest document revision.
Quick Links:
| Removal of the Junction Box JB4 | AMM 24-00-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 | AMM 24-00-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB4 Circuit-Cards | AMM 24-00-06-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 Circuit-Cards | AMM 24-00-06-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Secondary-Power Distribution Assemblies |
AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies |
AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Cross-Bleed Valve | AMM 36-11-29-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Cross-Bleed Valve | AMM 36-11-29-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Management Controller | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Management Controller | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect L35P1 from the XSBLEED valve.
- With A/C power on, select the XBLEED switch to "CLSD".
- Using a multimeter, measure for 28 VDC between connectors of Cross Bleed Valve as follows:
From To Expected Result Result L35P1-3 L35P1-6 28 VDC - If there is no 28 VDC, go to step 10.
- If there is 28 VDC continue with next step.
- Select XBLEED switch to "OPEN" and measure for 28 VDC between connectors of Cross Bleed Valve as follows:
From To Expected Result Result L35P1-4 L35P1-6 28 VDC - If there is no 28 VDC, go to step 10.
- If there is 28 VDC, continue with next step.
- Select XBLEED switch to "CLSD" and connect a ground to L35P1-5.
- In CAIMS, go to "SYSTEM DIAG", Chap. 36, BMC 2, "LRU TEST" and on Discrete & Analog input data page, check position of Cross Bleed Valve.
- If NO, go to step 8.
- If indicated "FULL CLOSED", continue with next step.
- Select XBLEED switch to "OPEN", remove the ground from L35P1-5 and connect to L35P1-1. On Discrete & Analog input data page, check position of Cross Bleed Valve.
- If indicated "FULL OPEN", replace defective XBLEED VALVE and do close out.
- If NO, continue with next step.
- Swap BMC 2 and BMC 1.
- If system checks are good, replace BMC 2 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks of all wires between BMC 2 and the XBLEED VALVE.
- If wiring checks are not good, repair defective wiring as required or replace JB4/PCB3 and do close out.
- If wiring checks are good, continue with next step.
- Swap SPDA 3 and SPDA 4.
- If system checks are good, replace SPDA 3 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks of all wires between SPDA3 and the XBLEED VALVE.
- If wiring checks are not good, repair defective wiring as required and continue with next step.
- If wiring checks are good, go to step 13.
- Replace JB4/PCB2 or JB4/PCB3.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Verify relay K15P1 for proper operation.
- Do close out.