06/22/21
Message Overview:
Message Name:
COMPRESSOR DISCHARGE OVERHEAT
| Identifier: | 216OBS001 |
| Effectivity: | All |
| System: | Cooling |
| Associated CAS: | None |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | None |
Message Description:
An overheat condition is detected at the outlet of the compressor stage of the LH/RH air cycle machine.
Possible Causes:
- High drift of the Compressor Discharge Temperature Sensor
- Ram Air Duct
- Dual Heat Exchanger is clogged at the Ram Air Inlet side
- Air Cycle Machine does not turn.
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
None
Troubleshooting Recommendations:
- Perform the following CAIMS troubleshooting
- [ACSC1-A] LH COMPRESS DIS OVERHEAT (2161515ECS)
- [ACSC1-B] LH COMPRESS DIS OVERHEAT (2162515ECS)
- [ACSC2-A] RH COMPRESS DIS OVERHEAT (2163515ECS)
- [ACSC2-B] RH COMPRESS DIS OVERHEAT (2164515ECS)
- Do close out.