06/22/21
Message Overview:
Message Name:
DUCT OVERHEAT
| Identifier: | 216OBS002 |
| Effectivity: | All |
| System: | Cooling |
| Associated CAS: | None |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | None |
Message Description:
An overheat condition of the forward duct, aft duct or cockpit duct is detected.
Possible Causes:
- Duct Temperature sensor
- Interface wiring of the Duct Temperature Sensor
- Ventilated Temperature Sensor
- Interface wiring of the Ventilated Temperature Sensor
- Trim Air Valve
- Interface wiring of the Trim Air Valve
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
None
Troubleshooting Recommendations:
- Perform the following CAIMS troubleshooting:
- [ACSC1-A] AFT DUCT OVERHEAT (2161518ECS)
- [ACSC1-B] AFT DUCT OVERHEAT (2162518ECS)
- [ACSC1-A] FWD DUCT OVERHEAT (2161517ECS)
- [ACSC1-B] FWD DUCT OVERHEAT (2162517ECS)
- [ACSC2-A] CKPT DUCT OVERHEAT (2163518ECS)
- [ACSC2-B] CKPT DUCT OVERHEAT (2164518ECS)
- Do close out.