06/22/21
Message Overview:
Message Name:
VENTILATED TEMPERATURE SENSOR INDICATION ON THE PMAT IS OUT OF TOLERANCE COMPARED WITH THE AMBIENT TEMPERATURE
| Identifier: | 216OBS008 |
| Effectivity: | All |
| System: | Air Conditioning |
| Associated CAS: | None |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | None |
Message Description:
ACSC receives an incorrect temperature signal from a ventilated temperature sensor.
Possible Causes:
- Cabin ventilated temperature sensor E15/E16
- Cockpit ventilated temperature sensor E20
- Interface wiring between SPDA2, cabin duct temperature sensors and ACSC1
- Interface wiring between SPDA1, cockpit duct temperature sensor and ACSC2
- JB5
- ACSC1
- ACSC2
- SPDA1
- SPDA2
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Troubleshooting Recommendations:
- Perform the following CAIMS troubleshooting:
- Do close out.