Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/01/24

Message Overview:

Message Name:

SLAT LEFT RESOLVER/ SFCU/ WRG

Message Code:

2750013STD

Associated CAS:

SLAT FAIL
(Caution)

SLAT FAULT
(Caution)

SLAT FLAP FAIL
(Caution)

SLAT FLAP FAULT
(Caution)

SLAT FLAP HALFSPD
(Advisory)

SLAT HALFSPD
(Advisory)

Reporting LRU: Slat/Flap Control Unit (SFCU)
System Description: 27-52-00 - Leading Edge Slat System
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
27-50-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
27-50-05 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Message Description:

The Slat/Flap Control Unit (SFCU) does not receive input from the Left Wing Slat Resolver or the input is not in the permitted range.

Possible Causes:

  • Left Slat Resolver (MT77)
  • Slat/Flap Control Unit (SFCU) 1 (A124)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW 700-27-0373 - SFCU -17: "SLAT-FLAP HALFSPD" EICAS Nuisance Message

Forum Articles/Infoservice/Newsletter: None

Flight Operations Notifications Manual (FONM): None

NOTES:

  • The resolvers are used by the SFCU for surface position acquisition.

Quick Links:

Removal of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Slat Resolvers AMM 27-53-41-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat Resolvers AMM 27-53-41-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. On the EMS CDU, select CTRL function and SLAT/FLAP RESET.
  2. NOTE: Wait at least one minute after SFCU reset to allow self-test to run.
  3. Cycle the SLATs from IN/0 degrees to OUT/30 degrees. Is the fault still present?

    1. If YES, continue with next step.
    2. If NO, do close out.

  4. Swap SFCU1 with SFCU2.

    1. If system checks are good, replace SFCU 1 and do close out.
    2. If fault remains, continue with next step.

  5. Move the SFCL to a different detent. Is the fault still present?

    1. If YES, continue with next step.
    2. If NO, do close out.
      NOTE: SFCU 1 is the left side ( channel 1 ) controller. SFCU 2 is the right side (channel 2) controller.

  6. Perform a resistance check from the applicable resolver channel SFCU rack connector through the Left Slat resolver.

    From the SFCU1, (resolver channel #1)

    From To Expected Result Result
    A124AP1-1 A124AP1-2 140 to 220 ohms (Resolver Primary Coil R2-R1)
    A124AP1-33 A124AP1-34 13 to 24 ohms (Output Sine Coil ch. 1)
    A124AP1-46 A124AP1-47 13 to 24 ohms (Output Cosine Coil ch.1)

    From the SFCU2, (resolver channel #2)

    From To Expected Result Result
    A95AP1-1 A95AP1-2 140 to 220 ohms (Resolver Primary Coil R2-R1)
    A95AP1-33 A95AP1-34 13 to 24 ohms (Output Sine Coil ch. 1)
    A95AP1-46 A95AP1-47 13 to 24 ohms (Output Cosine Coil ch. 1)

    1. If resistance is out of tolerance, replace defective resolver.
    2. If resistance is within range, continue with next step.

  7. Perform wiring check between the applicable SFCU rack connector and the Left SLAT resolver connector.
    From the SFCU 1, (resolver channel #1)

    From To Expected Result Result
    MT77-1 A124AP1-2 Continuity
    MT77-2 A124AP1-1 Continuity
    MT77-6 A124AP1-34 Continuity
    MT77-5 A124AP1-33 Continuity
    MT77-3 A124AP1-47 Continuity
    MT77-4 A124AP1-46 Continuity

    From the SFCU 2, (resolver channel 2):

    From To Expected Result Result
    MT77-7 A95AP1-2 Continuity
    MT77-8 A95AP1-1 Continuity
    MT77-12 A95AP1-34 Continuity
    MT77-11 A95AP1-33 Continuity
    MT77-9 A95AP1-47 Continuity
    MT77-10 A95AP1-46 Continuity

    1. If wiring defects are found, repair defective wiring as required and do close out.
    2. If no defects are found, continue with next step.

  8. Replace Left wing SLAT resolver.
  9. Do close out.