06/28/19
Message Overview:
Fault Message:
LEFT OUTBD GND SPLR ACTR FAULT
Fault Code:
27656181SX
Associated CAS:
| Reporting LRU: | Flight Control Unit (FCU) 1 |
| System Description: | 27-60-00 |
| Schematic Diagram: | 27-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-60-09 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The left outboard Ground Spoiler Actuator is defective detected by the Flight Control Unit (FCU) 1.
Possible Causes:
- Left Outboard Ground Spoiler Actuator
- Left Outboard Ground Spoiler (GS) Proximity Switch Sensor (PSS) (MT121)
- Flight Control Unit (FCU) 1 (A65)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
This fault may sometimes be cleared by performing the flight control system reset procedure.
Quick Links:
| Removal of the Flight-Control Units | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Flight-Control Units | AMM 27-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Spoiler Proximity Switch Sensors | AMM 27-61-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Spoiler Proximity Switch Sensors | AMM 27-61-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Ground-Spoiler Power Control Units (PCU) | AMM 27-63-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Ground-Spoiler Power-Control Units (PCU) | AMM 27-63-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Did the Spoilers deploy at the time of failure?
- If NO, go to step 6.
- If YES, continue with next step.
- Access and disconnect FCU 1 Connector A65EP1 and Left Outboard GS Prox Sensor Connector MT121P1. Perform a continuity check as follows:
From To Result MT121P1-A Ground MT121P1-B Ground MT121P1-A MT121P1-B - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result MT121P1-A A65EP1-7K MT121P1-B A65EP1-7J - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Swap FCU 1 with FCU 2. Is the fault still present?
- If NO, replace FCU 1 and do close out.
- If YES, continue with next step.
- Replace the Left outboard GS Proximity Switch Sensor.
- Deploy the ground actuator by using the hydraulic lock override feature. Cycle the Ground Spoiler surface 3-4 times.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Left Outboard Ground Spoiler Actuator.
NOTE: The FCU is able to differentiate between a defective selector valve and a defective actuator. - Do close out.