07/04/19
Message Overview:
Fault Message:
RH MFS #1 ACTUATOR/WRG FAULT
Fault Code:
27656231SX
Associated CAS:
| Reporting LRU: | Flight-Control Unit (FCU) 1 |
| System Description: | 27-60-00 |
| Schematic Diagram: | 27-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-60-10 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
There is a problem with the Right Multi Function Spoiler (MFS) 1 Actuator and detected by the Flight Control Unit 1 channel B. The Right MFS 1 failed to deploy.
Possible Causes:
- Right Multi Function Spoiler (MFS) Power Control Unit (PCU) 1 (B47)
- Flight Control Unit (FCU) 1 (A65)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
This fault may sometime be cleared by performing the flight control system reset procedure. If the fault clears, swap FCU positions.
Getting access to the right MFS actuator #1 connector, to check for/remove any corrosion may clear the condition on the a/c.
The right MFS#1 data can be found in CAIMS:
- SYSTEM DIAG.
- 27-00 FLIGHT CONTROLS.
- FLIGHT CONTROL UNIT #1.
- LRU TEST.
- DISPLAY SPOILER DATA.
- CONFIRM.
- Go to sheets 1/3.
And
Quick Links:
| Removal of the Flight-Control Units | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Flight-Control Units | AMM 27-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Multi-Function Spoiler Power-Control-Units (PCU) | AMM 27-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Multi-Function Spoiler Power-Control-Units (PCU) | AMM 27-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect the right MFS 1 connector (B47) to check for corrosion on the pins and sockets.
- If system checks are good, do close out.
- If fault remains, continue with next step.
NOTE: Use contact cleaner.
- Swap FCU 1 with FCU 2.
- If system checks are good, replace FCU 1. Reset FCUs latched faults and do close out.
- If fault remains, continue with next step.
NOTE: If the fault follows the FCU, it will posted on the right MFS 3.
- Perform wiring checks between FCU 1 and MFS 1.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace Right MFS 1 PCU.
- Do close out.