07/08/19
Message Overview:
Fault Message:
CPLT MASTER DISCONNECT SW/WRG FAULT
Fault Code:
27657240SX
Associated CAS:
| Reporting LRU: | Flight-Control Unit (FCU) |
| System Description: | 27-60-00 |
| Schematic Diagram: | 27-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-60-06 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Copilot Master-Disconnect Switch is defective as monitored by the Flight-Control Unit (FCU). There are four sets of contacts in the Master Disconnect Switch. The Stabilizer/Pitch Trim System uses two sets. These two sets of contacts are usually closed.
Possible Causes:
- Copilot Master Disconnect Switch (S44)
- Flight-Control Unit (FCU) 1 (A65)
- Flight-Control Unit (FCU) 2 (A66)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Master Disconnect Switches | AMM 22-12-17-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Master Disconnect Switches | AMM 22-12-17-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Flight-Control Units | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Flight-Control Units | AMM 27-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- If the fault message COPILOT MASTER DISC SWITCH FAULT was recorded from the FCU 1 and FCU 2, check copilot master disconnect switch continuity, wiring and functionality.
- If the fault message COPILOT MASTER DISC SWITCH FAULT was recorded from the FCU 1 only, perform wiring checks between FCU 1 (A65DP1) and copilot master disconnect switch.
- If wiring checks are good, swap FCU.
- If system checks are good, replace defective FCU. Reset FCUs latched faults and do close out.
- If fault remains, go to step 3.
- If wiring checks are not good, repair defective wiring as required and continue with next step.
- If wiring checks are good, swap FCU.
- If the fault message COPILOT MASTER DISC SWITCH FAULT was recorded from the FCU 2 only, perform wiring checks between FCU 2 (A66DP1) and copilot master disconnect switch.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace defective FCU.
- Do close out.