06/27/19
Message Overview:
Fault Message:
270 VDC LINK REGEN #1
Fault Code:
2750147STD
Associated CAS:
| Reporting LRU: | Slat/Flap Control Unit (SFCU) |
| System Description: | 27-52-00 |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
This message shows when one of the conditions that follow occurs:
- 270 VDC link internal to the Slat/Flap Control Unit (SFCU) is out of normal limits for more than 0.08 seconds OR,
- There is an internal failure of the Motor Regenerative Resistor Circuit
Possible Causes:
- Slat/Flap Control Unit (SFCU) 1 (A124)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
If the SLAT FLAP PWR 1 thermal breaker is tripped on the CCBP, do not reset circuit breaker for troubleshooting. Make sure there is no short circuit, then replace SFCU 1.
Quick Links:
| Removal of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access CAIMS System diagnostic and unlatch the fault in the SFCU 1.
- SYSTEM DIAG
- 27-00 FLIGHT CONTROLS
- SLAT/FLAP CONTROL UNIT #1(2)
- LRU TEST
- CLEAR LATCHED FAULT - SFCU1
- Highlight "CLEAR LATCHED FAULTS" and "SELECT"
- On the EMS CDU, select CTRL function and SLAT/FLAP RESET.
NOTE: Wait at least one minute after SFCU reset to allow self-test to run.- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap SFCU 1 with SFCU 2.
NOTE: If necessary, unlatch the fault in CAIMS and perform a SLAT/FLAP RESET after swapping the SFCUs.- If system checks are good, replace SFCU 1 and do close out.
- If fault remains, continue with next step.
- Measure the AC voltage on the SFCU 1 and make sure the three phases are reading the same voltage.
SFCU 1 Voltage A124BP1-6 115 VAC A124BP1-7 115 VAC A124BP1-8 115 VAC - If voltages are the same, do close out.
- If voltages are different, continue with next step.
- Perform wiring checks between SFCU and CCBP. Repair as required.
- Do close out.