06/22/21
Message Overview:
Message Name:
TEMPERATURE CONTROL VALVE - NO DATA
| Identifier: | 215OBS016 |
| Effectivity: | All |
| System: | Air Conditioning System |
| Associated CAS: | None |
| System Description: | 21-52-00 |
| Schematic Diagram: | 21-52-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | None |
Message Description:
The data from one or both temperature control valves is missing.
Possible Causes:
- Interface Wiring between Temperature Valve and Air-Conditioning System Controller (ACSC) 1
- Temperature Control Valve
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
Troubleshooting Recommendations:
- Perform the following CAIMS troubleshooting:
- [ACSC1-A] LH TEMP CONT VLV CMD /TCV (2161320ECS)
- [ACSC1-B] LH TEMP CONT VLV CMD /TCV (2162320ECS)
- [ACSC2-A] RH TEMP CONT VLV CMD /TCV (2163320ECS)
- [ACSC2-B] RH TEMP CONT VLV CMD /TCV (2164320ECS)
- Do close out.