Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

Fault Description:

There is a problem with the Flight Control Unit (FCU) 1 or the related interface wiring.

Possible Causes:

  • Flight Control Unit (FCU) 1 (A65)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

This fault could be related to a real issue with the flight control system but not related to a faulty flight control unit. The flight control unit command and monitoring lane within each channel are sometime not able to confirm a fault at the same time related to the flight control system. In this condition a single or many CAS messages will be posted and require troubleshooting. This fault may sometime be cleared by performing the flight control system reset procedure. If the fault clears, Swap FCU positions.

Quick Links:

Removal of the Flight-Control Units AMM 27-61-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Flight-Control Units AMM 27-61-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Self-Test (SPOST) of the Flight-Control Units AMM 27-61-05-740-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to System Diagnostics AMM 45-45-00-970-804 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Non-Volatile Memory (NVM) Management AMM 45-45-00-970-822 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Perform a self test of FCU to confirm that the fault remains the same.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. Swap FCU 1 with FCU 2.

    1. If system checks are good, replace FCU 1. Reset FCUs latched faults and do close out.
    2. If fault remains, continue with next step.

  3. Perform wiring checks between the following contacts:

    From To Result
    A65AP1-1H A65AP1-15D
    A65AP1-2H A65AP1-15C
    A65AP1-1D A65AP1-5B
    A65AP1-1C A65AP1-5A
    A65AP1-3K A65AP1-8J
    A65AP1-2D A65AP1-5D

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  4. Perform a NVM download of both FCUs and send the download data to ac.yul@aero.bombardier.com.
  5. Do close out.