08/05/19
Message Overview:
Fault Message:
FWC 3 - EXTERNAL ASCB FAULT
Fault Code:
3151009FW3
Associated CAS:
| Reporting LRU: | None |
| System Description: | 31-44-00 |
| Schematic Diagram: | 31-44-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 31-44-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Aircraft Avionics Standard Communications Buses (ASCB) member system data through ASCB data that is usually transmitted on the primary and secondary ASCB is incorrect, is available on only one bus or is not available at all.
Possible Causes:
- Right BAC Avionics Standard Communications Buses (ASCB) Isolation Coupler (A100)
- Right PRI Avionics Standard Communications Buses (ASCB) Isolation Coupler (A236)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
For in depth ASCB BUS Troubleshooting Recommendations: and test equipment detail, refer to the ASCB Fault Isolation Guide.
Quick Links:
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Integrated Maintenance Test (IMT) Fault Code Look-Up | AMM 45-45-00-970-826 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the CAIMS PMAT, get access to system diagnostics and perform the IAC EDS/Core Test.
- After each test is completed, look for the TEST RESULTS page and record the fault type and code(s) for each IMT fault.
- Perform the IMT fault code look-up procedure to find the applicable troubleshooting procedures.
- Carry out troubleshooting procedures.
- Do close out.