Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

08/13/19

Message Overview:

Fault Message:

APU NO ACCELERATION

Fault Code:

4960132APU

Associated CAS:

APU SHUTDOWN
(Advisory)

Reporting LRU: Full Authority Digital Engine (Electronic) Control (FADEC)
System Description: 49-40-00
Schematic Diagram: 49-61-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 49-12-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
49-61-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

After ignition occurs, the acceleration rate is less than 0.05%/sec for 15 seconds or more. In this condition, the Full Authority Digital Engine (Electronic) Control (FADEC) will cause an Auxiliary Power Unit (APU) shutdown.

The Correlated Fight Deck Effect (FDE) is the Engine Indication and Crew Alerting System (EICAS) advisory message APU SHUTDOWN.

Possible Causes:

  • Inlet Pressure Sensor (MT1)
  • Inlet Temperature Sensor (MT3)
  • Exhaust-Gas Temperature (EGT) sensor (TC1)
  • Fuel-Control Torque Motor
  • Fuel Solenoid Valve (V2)
  • Fuel Flow-Divider Valve
  • Load Control Valve (MPE1)
  • Surge Valve (MPE2)
  • Starter Motor (B55)
  • Fuel Control Unit (FCU) (A3)
  • De-Prime Valve (V1)
  • Auxiliary Power Unit (APU)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the APU Generator AMM 24-22-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the APU Generator AMM 24-22-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Engine Branched Wiring-Harness AMM 49-12-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Engine Branched Wiring-Harness AMM 49-12-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Inlet-Duct Forward Section AMM 49-15-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Inlet-Duct Forward Section AMM 49-15-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Fuel Control Unit AMM 49-30-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Fuel Control Unit AMM 49-30-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Fuel Solenoid Valve AMM 49-30-17-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Fuel Solenoid Valve AMM 49-30-17-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Fuel Flow-Divider Valve AMM 49-30-21-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Fuel Flow-Divider Valve AMM 49-30-21-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Starter Motor AMM 49-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Starter Motor AMM 49-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the De-Prime Valve AMM 49-90-24-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the De-Prime Valve AMM 49-90-24-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Check for fault message as follow:

  2. Examine the engine branched wiring-harness for bare wiring, kinks, worn areas and other damage (WM 49-12).

    1. If there is bare wiring, kinks, worn areas or other damage, replace engine branched wiring-harness and do close out.
    2. If there is no bare wiring, kinks, worn areas or other damage, continue with next step.

  3. Check for fault message APU SHUTDOWN (Advisory) shows on the EICAS primary display.

    1. If fault messages is not active, do close out.
    2. If fault message message is active, continue with next step.

  4. Examine the inlet door for blockage.

    1. If the inlet door has blockage, remove blockage and do close out.
    2. If the inlet door has no blockage, continue with next step.

  5. Check for fault message APU SHUTDOWN (Advisory) still shows on the EICAS primary display.

    1. If fault messages is not active, do close out.
    2. If fault message message is active, continue with next step.

  6. Open the APU inlet door, examine the inlet-duct forward section for blockage using a optic fiber borescope (borescope) through the inlet door.

    1. If the inlet-duct forward section has blockage, remove the blockage and do close out.
    2. If the inlet-duct forward section has no blockage, continue with next step.

  7. Check for fault message APU SHUTDOWN (Advisory) still shows on the EICAS primary display.

    1. If fault messages is not active, do close out.
    2. If fault message message is active, replace starter motor and continue with next step.

  8. Check for fault message APU SHUTDOWN (Advisory) still shows on the EICAS primary display.

    1. If fault messages is not active, do close out.
    2. If fault message message is active, replace fuel control unit and continue with next step.

  9. Check for fault message APU SHUTDOWN (Advisory) still shows on the EICAS primary display.

    1. If fault messages is not active, do close out.
    2. If fault message message is active, replace the fuel solenoid valve and continue with next step.

  10. Check for fault message APU SHUTDOWN (Advisory) still shows on the EICAS primary display.

    1. If fault messages is not active, do close out.
    2. If fault message message is active, replace the fuel flow-divider valve and continue with next step.

  11. Check for fault message APU SHUTDOWN (Advisory) still shows on the EICAS primary display.

    1. If fault messages is not active, do close out.
    2. If fault message message is active, replace the de-prime valve and continue with next step.

  12. Check for fault message APU SHUTDOWN (Advisory) still shows on the EICAS primary display.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  13. Replace APU.
  14. Do Close out.